QAR1,400.00
IDNet 2+2 Module, 250 point capacity; electrically isolated output with four short circuit isolating Class B or Class A output loops; alarm currents for 50 and above devices includes 20 device LEDs in alarm.
-

QAR40.00
Remote LED Alarm Indicator Mounted on a Single Gang Stainless Steel Plate
-

QAR120.00
The Simplex 2975-9178 is a heavy-duty, surface-mount steel back box designed specifically to house and protect Simplex addressable fire alarm manual pull stations.
-

QAR3,900.00
4007ES fire alarm control units (FACUs) provide extensive installation, operator, and service features with point and module capacities suitable for a wide range of system applications. FACUs are configurable for stand-alone or networked fire control operation. The convenient and intuitive color touchscreen provides easy access for typical system response actions and for detailed system review or configuration updates with password control to limit user access. IDNet 2 addressable initiation communications and IDNAC addressable notification communications are standard features. Refer to data sheet S4007-0001 for 4007ES FACUs providing conventional notification
-

-

QAR145.00
The Simplex 4090-9002 is a compact Relay Individual Addressable Module (Relay IAM) designed to provide precise, remote auxiliary control through a Simplex fire alarm control panel. It utilizes the IDNet communication loop to draw both operating power and data, significantly streamlining installation and reducing wiring complexity.
-

QAR210.00
The Simplex 4090-9007 Signal Individual Addressable Module (IAM) is an IDNet-compatible peripheral designed to provide a remote, supervised, and addressable interface between conventional notification appliances and a host fire alarm control panel (FACU)
-

QAR150.00
4090-9116 Addressable IDNet Communications Isolators provide IDNet communications isolation to improve installation convenience and increase system integrity. Isolation is automatically activated when an output short circuit is detected and isolation can also be selected manually from the control panel to assist with troubleshooting wiring problems. Isolators power-up in isolation mode and are directed to connect by the control panel. If the output wiring is acceptable, the isolator will connect to the rest of the circuit. If the output wiring is shorted, the isolator remains isolated. The isolator reports back to the panel when it is in isolation mode and the extent of shorted wiring is reported back to the panel by identifying device addresses that are not communicating. [Isolators are assigned sequentially to low number addresses to expedite SLC power-up.] During installation, earth faults frequently occur. Finding these faults normally requires extensive wiring disconnection. With the 4090-9116 Addressable IDNet Isolator, earth faults on the IDNet communications lines can be quickly located to assist in their repair and to restore the system wiring to normal.
-

QAR160.00
Trim plate, galvanized steel, with LED viewing window; includes mounting screws.
-

-

QAR75.00
Description
The Simplex 4098-9733 is a TrueAlarm analog addressable heat sensor designed for use with compatible Simplex IDNet or MAPNET II fire alarm control units. It digitally transmits analog temperature data to the control panel, where alarm decisions are made based on programmable fixed temperature and optional rate-of-rise criteria. The sensor provides selectable fixed temperature operation at 135°F (57.2°C) or 155°F (68°C), with optional rate-of-rise detection selectable at 15°F or 20°F per minute (8.3°C or 11.1°C per minute). The device is self-restoring and uses rate-compensated sensing for accurate local temperature measurement. TrueAlarm processing at the control unit includes peak value logging, environmental compensation, and NFPA 72 compliant sensitivity monitoring. The sensor mounts to compatible 4098-series TrueAlarm bases (sold separately).
-

QAR550.00
The Simplex 4098-9755 is a compact addressable duct smoke sensor housing designed for detecting smoke within HVAC duct systems. It includes a factory-installed 4098-9714 TrueAlarm photoelectric smoke sensor and operates using IDNet or MAPNET II two-wire communications, which also supply its operating power.
This model provides intelligent analog sensing, digitally transmitting sensor data to the fire alarm control panel for analysis, environmental compensation, and programmable sensitivity management. The control panel determines alarm thresholds, monitors sensor dirt accumulation, logs peak activity, and performs automatic calibration checks to reduce nuisance alarms.
The 4098-9755 does not include relay outputs (basic housing model). A clear polycarbonate cover allows visual inspection, and built-in test ports enable functional smoke testing without removing the cover. Sampling tubes are ordered separately and selected based on duct width.
This duct housing is UL listed to UL 268A for duct applications and is intended as a secondary detection device within HVAC systems, not as a substitute for open-area smoke detection.