The Edwards SIGA-IM2 Isolator Module is an addressable device that protects a signaling line circuit (SLC) from a to wire-to-wire short. The SIGA-IM2 module monitors line voltages and opens the data to detect a short, isolating the short between the two modules located closest to the short. The loop controller assigns an address to the SIGA-IM module. The module uses one detector address on the SLC.
The EM312SR module enables control of external devices in fire alarm systems through a supervised input, a supervised output for audible/visual indicators, and a volt-free relay output for devices such as electromagnets. It also includes an external supervised voltage input, a short-circuit isolator, three multicolor LEDs to indicate channel status, and automatic addressing via serial number. Compact and versatile, it is ideal for installations requiring maximum reliability.
The EM500 module is designed to control synoptic panels within loop-based systems. Consisting of two units supplied together, it includes the EM500 module, with 8 configurable LED outputs and 5 multifunction inputs, and the EM500-EXP expansion module, which adds 24 configurable LEDs and requires a 24V DC auxiliary power supply. Ideal for remote visualization of system status, it allows for flexible configuration and precise visual signaling.
Wall mount addressable visual/audible-alarm signaller, IP65 protection grade.
Volume, flash intensity and audio sequences selectable (and diversified according to circumstances) between the 14 tones
(and 16 messages in 8 different languages for the versions with voice functions) available on board the device. For models
with the voice alarm function, it is also possible to customize tones/voice messages by means of the EDRV2000.
The device is powered via the loop but is equipped with terminals for an optional separate power input.
Available in red or white casing
The EU311 micromodule range is designed for direct integration within devices to be controlled, thanks to its extremely compact size. The EU311 module features one supervised input and one loop-powered output, ideal for managing call points, sounders, or visual/audible indicators.
Variants include:
EU311C: input only micromodule non-supervised for control of buttons, identifies on the Loop as a call point
EU311CV: supervised input only, also identified as call point
EU311S: output only micromodule for control of alarm signalling devices, identifies on the Loop as a sounder
QAR90.00Original price was: QAR90.00.QAR85.00Current price is: QAR85.00.
DI-9103E Intelligent Rate of Rise and Fixed Temperature Heat Detector is a new addressable fire alarm device cooperating with GST intelligent fire alarm control panels to build a fire detection system. The detector shows fire alarm by the LED indicator and transmits the signal to the FACP.
The GST-IFP8 Intelligent Fire Alarm Control Panel configured with a 2-loop card (such as the Carrier LCIFP8 Dual Loop Card) creates a highly scalable, addressable fire safety solution. While the standalone GST-IFP8 main chassis is designed to expand up to 8 or 10 loops, pairing it with an initial 2-loop card provides immediate coverage for up to 484 addressable devices (242 devices per loop). This makes it an ideal, future-proof configuration for medium-sized facilities looking to scale up over time
GST200-2 Intelligent Fire Alarm Control Panel 2 loop addressable fire detection control panel with up to 242 devices per loop, the system is packed with features that are not usually associated with smaller and medium systems. The GST 200-2 provides a high-quality solution at an exceptional value. By utilizing advanced GST Protocol, the system is compatible with the complete range of GST intelligent Detectors, Sounders, Call Points, Interfaces, including gas extinguishing controls. Networkable with all GST intelligent fire control panels the system can be expanded up to a maximum of 240 GST panels (over 48,000 devices).
I-9403 Intelligent Sounder Strobe is an audible and visual alarm device installed in field, which can be activated by fire alarm control panel in fire control centre. After activated, it will generate strong audible and visual alarm signal to warn people in field.
A 25.5mm high shallow base and a 40mm high deep base are available. The sounder strobe comes with the shallow base. The deep base C-94DB should be ordered separately.