  • Simplex 4090-9116 Addressable IDNet Communications Isolator

    Simplex 4090-9116 Addressable IDNet Communications Isolator

    QAR150.00

    4090-9116 Addressable IDNet Communications Isolators provide IDNet communications isolation to improve installation convenience and increase system integrity. Isolation is automatically activated when an output short circuit is detected and isolation can also be selected manually from the control panel to assist with troubleshooting wiring problems. Isolators power-up in isolation mode and are directed to connect by the control panel. If the output wiring is acceptable, the isolator will connect to the rest of the circuit. If the output wiring is shorted, the isolator remains isolated. The isolator reports back to the panel when it is in isolation mode and the extent of shorted wiring is reported back to the panel by identifying device addresses that are not communicating. [Isolators are assigned sequentially to low number addresses to expedite SLC power-up.] During installation, earth faults frequently occur. Finding these faults normally requires extensive wiring disconnection. With the 4090-9116 Addressable IDNet Isolator, earth faults on the IDNet communications lines can be quickly located to assist in their repair and to restore the system wiring to normal.

  • Simplex 4090-9802 Trim Plate for Surface Mounted Box

    Simplex 4090-9802 Trim Plate for Surface Mounted Box

    QAR160.00

    Trim plate, galvanized steel, with LED viewing window; includes mounting screws.

  • Simplex 4098-9714 TrueAlarm Photoelectric Smoke Sensor

    Simplex 4098-9714 TrueAlarm Photoelectric Smoke Sensor

    Description

    The Simplex 4098-9714 is an addressable photoelectric smoke sensor designed for use with Simplex IDNet and MAPNET II two-wire communications. Using TrueAlarm analog sensing technology, the detector digitally transmits real-time smoke data to the control unit for precise analysis and reduced nuisance alarms. This model features a 360° smoke entry design for improved detection response from any direction and built-in insect screening to help maintain sensing chamber integrity. The control panel automatically adjusts sensitivity to compensate for dust and environmental changes, improving long-term reliability. Selectable sensitivity levels include 0.2%, 0.5%, and 1% per foot for special applications, with standard operation ranging from 1.25% to 3.1% per foot depending on panel programming. The 4098-9714 is compatible with Simplex 4007ES, 4010, 4010ES, 4100ES, 4100U, and 4008 Series control units with reduced feature set. It mounts to compatible TrueAlarm bases and is listed to UL 268 7th Edition. Operating temperature range is 15°F to 122°F. Ideal for commercial fire alarm systems requiring intelligent smoke detection and panel-based sensitivity control.
  • Simplex 4098-9733 TrueAlarm Addressable Heat Detector

    Simplex 4098-9733 TrueAlarm Addressable Heat Detector

    QAR75.00

    Description

    The Simplex 4098-9733 is a TrueAlarm analog addressable heat sensor designed for use with compatible Simplex IDNet or MAPNET II fire alarm control units. It digitally transmits analog temperature data to the control panel, where alarm decisions are made based on programmable fixed temperature and optional rate-of-rise criteria. The sensor provides selectable fixed temperature operation at 135°F (57.2°C) or 155°F (68°C), with optional rate-of-rise detection selectable at 15°F or 20°F per minute (8.3°C or 11.1°C per minute). The device is self-restoring and uses rate-compensated sensing for accurate local temperature measurement. TrueAlarm processing at the control unit includes peak value logging, environmental compensation, and NFPA 72 compliant sensitivity monitoring. The sensor mounts to compatible 4098-series TrueAlarm bases (sold separately).

  • Simplex 4098-9755 TrueAlarm Duct Sensor Housing

    Simplex 4098-9755 TrueAlarm Duct Sensor Housing

    QAR550.00

    The Simplex 4098-9755 is a compact addressable duct smoke sensor housing designed for detecting smoke within HVAC duct systems. It includes a factory-installed 4098-9714 TrueAlarm photoelectric smoke sensor and operates using IDNet or MAPNET II two-wire communications, which also supply its operating power.

    This model provides intelligent analog sensing, digitally transmitting sensor data to the fire alarm control panel for analysis, environmental compensation, and programmable sensitivity management. The control panel determines alarm thresholds, monitors sensor dirt accumulation, logs peak activity, and performs automatic calibration checks to reduce nuisance alarms.

    The 4098-9755 does not include relay outputs (basic housing model). A clear polycarbonate cover allows visual inspection, and built-in test ports enable functional smoke testing without removing the cover. Sampling tubes are ordered separately and selected based on duct width.

    This duct housing is UL listed to UL 268A for duct applications and is intended as a secondary detection device within HVAC systems, not as a substitute for open-area smoke detection.

  • Simplex 4098-9764 Photo Sensor with Heat, Simplex

    Simplex 4098-9764 Photo Sensor with Heat, Simplex

    QAR125.00

    The Simplex 4098-9764 is an addressable TrueAlarm multi-sensor detector that combines photoelectric smoke sensing and thermal heat sensing in a single housing. By continuously communicating analog data to a compatible Simplex fire alarm control unit (FACU), the system applies a “TrueSense” covariance algorithm to analyze both activities simultaneously. This dual-criteria evaluation allows the system to drastically reduce nuisance alarms while responding much faster to hot, flaming fires

  • Simplex 4098-9789 Sensor Base, Remote LED Connection

    Simplex 4098-9789 Sensor Base, Remote LED Connection

    QAR85.00

    Description

    TrueAlarm sensor bases include addressable electronics that monitor the detachable photoelectric or heat sensors at all times. The base digitizes each sensor’s output and sends it to the fire alarm control panel every four seconds.

    TrueAlarm sensors use the same base, so you can swap sensor types to match each location. You can also swap sensors during construction.

    When dust levels rise, install a heat sensor instead of covering a smoke sensor and taking it out of service. You do not need to reprogram the panel. The panel may show the wrong sensor type, but the heat sensor still runs at a default setting and provides heat detection at that spot.

  • Simplex 4098-9794 TrueAlarm Sounder Base With Remote LED

    Simplex 4098-9794 TrueAlarm Sounder Base With Remote LED

    QAR190.00

    The Simplex 4098-9794 is a modular TrueAlarm sounder base designed for use with compatible TrueAlarm photoelectric and heat sensor heads. It combines an audible notification appliance and an analog addressable sensor interface into a single ceiling- or wall-mounted device.

    The base provides a built-in piezoelectric sounder rated at 88 dBA minimum at 10 feet, operating from 24 VDC or from a compatible Notification Appliance Circuit (NAC). When NAC powered, sounder operation can be synchronized (Temporal, March Time, etc.) by the NAC. The sounder can also be manually activated from the control panel.

    TrueAlarm analog sensor information is digitally communicated to the fire alarm control panel via IDNet or MAPNET II communications. Address selection is base-mounted, allowing the programmed address to remain with the installed location even when the sensor head is removed for service.

    The 4098-9794 is listed to UL 268 for smoke detection (with compatible sensor) and UL 464 as an audible notification appliance.

  • Simplex 4099-9006 Addressable Double Action Pull Station

    Simplex 4099-9006 Addressable Double Action Pull Station

    QAR160.00

    The Simplex 4099-9006 is an individually addressable manual fire alarm station designed for use with Simplex IDNet or MAPNET II communications systems. This model features double-action push operation, requiring the operator to push a spring-loaded interference plate before pulling the lever to initiate an alarm.

    The integral addressable module (IAM) continuously monitors status and communicates changes to the connected Simplex fire alarm control panel over a single pair of wires. A visible LED indicator flashes during communications and remains steady when activated. The pull lever latches in the alarm position and protrudes from the housing to provide a clear visual indication.

    The 4099-9006 is constructed of durable Lexan polycarbonate, supports surface or semi-flush mounting, and is UL listed to Standard 38. It is NEMA 1 rated when used with the appropriate back box.

  • Simplex 4100-3109 IDNet 2 Module, 250 Point Capacity

    Simplex 4100-3109 IDNet 2 Module, 250 Point Capacity

    QAR1,400.00
    The Simplex 4100-3109 (Hardware PCB Part Number: 566-239) is a high-performance IDNet 2 addressable loop interface card designed for Simplex 4100ES and 4100U Fire Alarm Control Panels (FACPs). This crucial expansion module acts as the central communication hub between your fire alarm control panel and intelligent, addressable field devices.
    Engineered for flexibility and robust survivability, this IDNet 2 card manages up to 250 addressable points across its signaling line circuits (SLCs), providing reliable data transmission and power to addressable smoke detectors, heat detectors, monitor modules, and control points.
  • Simplex 4100-5401 ES Power Supply Module

    Simplex 4100-5401 ES Power Supply Module

    QAR2,250.00

    The Simplex 4100-5401 ES-PS Power Supply Module is a primary system power supply designed for Simplex 4100ES addressable fire alarm control units. It provides regulated system power, battery charging, auxiliary outputs, and expansion capability for compatible option cards installed in the control panel.

    The module operates from a 120–240 VAC input and converts power to regulated 24 VDC for the fire alarm control panel and connected field devices. It also includes a dual-rate, temperature-compensated battery charger capable of charging sealed lead-acid batteries up to 110 Ah when used with an external battery cabinet.

  • Simplex 4100-9701 ES-PS Master Controller

    Simplex 4100-9701 ES-PS Master Controller

    QAR13,500.00
    The Simplex 4100-9701 is a core hardware assembly for the Simplex 4100ES Fire Alarm Control Panel (FACP). Specifically, this part number designates the ES-PS Master Controller Bay equipped with an English 2×40 character LCD user interface.
    While a base master controller natively includes a standard dual-loop card, your specific system configuration contains 4 Addressable Loops (achieved via an expansion module) and 2 Notification Appliance Circuits (NACs).