Armor Fire

Simplex

Showing 13–24 of 27 results

  • Simplex 4098-9733 TrueAlarm Addressable Heat Detector

    Simplex 4098-9733 TrueAlarm Addressable Heat Detector

    QAR75.00

    Description

    The Simplex 4098-9733 is a TrueAlarm analog addressable heat sensor designed for use with compatible Simplex IDNet or MAPNET II fire alarm control units. It digitally transmits analog temperature data to the control panel, where alarm decisions are made based on programmable fixed temperature and optional rate-of-rise criteria. The sensor provides selectable fixed temperature operation at 135°F (57.2°C) or 155°F (68°C), with optional rate-of-rise detection selectable at 15°F or 20°F per minute (8.3°C or 11.1°C per minute). The device is self-restoring and uses rate-compensated sensing for accurate local temperature measurement. TrueAlarm processing at the control unit includes peak value logging, environmental compensation, and NFPA 72 compliant sensitivity monitoring. The sensor mounts to compatible 4098-series TrueAlarm bases (sold separately).

  • Simplex 4098-9755 TrueAlarm Duct Sensor Housing

    Simplex 4098-9755 TrueAlarm Duct Sensor Housing

    QAR550.00

    The Simplex 4098-9755 is a compact addressable duct smoke sensor housing designed for detecting smoke within HVAC duct systems. It includes a factory-installed 4098-9714 TrueAlarm photoelectric smoke sensor and operates using IDNet or MAPNET II two-wire communications, which also supply its operating power.

    This model provides intelligent analog sensing, digitally transmitting sensor data to the fire alarm control panel for analysis, environmental compensation, and programmable sensitivity management. The control panel determines alarm thresholds, monitors sensor dirt accumulation, logs peak activity, and performs automatic calibration checks to reduce nuisance alarms.

    The 4098-9755 does not include relay outputs (basic housing model). A clear polycarbonate cover allows visual inspection, and built-in test ports enable functional smoke testing without removing the cover. Sampling tubes are ordered separately and selected based on duct width.

    This duct housing is UL listed to UL 268A for duct applications and is intended as a secondary detection device within HVAC systems, not as a substitute for open-area smoke detection.

  • Simplex 4098-9764 Photo Sensor with Heat, Simplex

    Simplex 4098-9764 Photo Sensor with Heat, Simplex

    QAR125.00

    The Simplex 4098-9764 is an addressable TrueAlarm multi-sensor detector that combines photoelectric smoke sensing and thermal heat sensing in a single housing. By continuously communicating analog data to a compatible Simplex fire alarm control unit (FACU), the system applies a “TrueSense” covariance algorithm to analyze both activities simultaneously. This dual-criteria evaluation allows the system to drastically reduce nuisance alarms while responding much faster to hot, flaming fires

  • Simplex 4098-9789 Sensor Base, Remote LED Connection

    Simplex 4098-9789 Sensor Base, Remote LED Connection

    QAR85.00

    Description

    TrueAlarm sensor bases include addressable electronics that monitor the detachable photoelectric or heat sensors at all times. The base digitizes each sensor’s output and sends it to the fire alarm control panel every four seconds.

    TrueAlarm sensors use the same base, so you can swap sensor types to match each location. You can also swap sensors during construction.

    When dust levels rise, install a heat sensor instead of covering a smoke sensor and taking it out of service. You do not need to reprogram the panel. The panel may show the wrong sensor type, but the heat sensor still runs at a default setting and provides heat detection at that spot.

  • Simplex 4098-9794 TrueAlarm Sounder Base With Remote LED

    Simplex 4098-9794 TrueAlarm Sounder Base With Remote LED

    QAR190.00

    The Simplex 4098-9794 is a modular TrueAlarm sounder base designed for use with compatible TrueAlarm photoelectric and heat sensor heads. It combines an audible notification appliance and an analog addressable sensor interface into a single ceiling- or wall-mounted device.

    The base provides a built-in piezoelectric sounder rated at 88 dBA minimum at 10 feet, operating from 24 VDC or from a compatible Notification Appliance Circuit (NAC). When NAC powered, sounder operation can be synchronized (Temporal, March Time, etc.) by the NAC. The sounder can also be manually activated from the control panel.

    TrueAlarm analog sensor information is digitally communicated to the fire alarm control panel via IDNet or MAPNET II communications. Address selection is base-mounted, allowing the programmed address to remain with the installed location even when the sensor head is removed for service.

    The 4098-9794 is listed to UL 268 for smoke detection (with compatible sensor) and UL 464 as an audible notification appliance.

  • Simplex 4099-9006 Addressable Double Action Pull Station

    Simplex 4099-9006 Addressable Double Action Pull Station

    QAR160.00

    The Simplex 4099-9006 is an individually addressable manual fire alarm station designed for use with Simplex IDNet or MAPNET II communications systems. This model features double-action push operation, requiring the operator to push a spring-loaded interference plate before pulling the lever to initiate an alarm.

    The integral addressable module (IAM) continuously monitors status and communicates changes to the connected Simplex fire alarm control panel over a single pair of wires. A visible LED indicator flashes during communications and remains steady when activated. The pull lever latches in the alarm position and protrudes from the housing to provide a clear visual indication.

    The 4099-9006 is constructed of durable Lexan polycarbonate, supports surface or semi-flush mounting, and is UL listed to Standard 38. It is NEMA 1 rated when used with the appropriate back box.

  • Simplex 4100-3109 IDNet 2 Module, 250 Point Capacity

    Simplex 4100-3109 IDNet 2 Module, 250 Point Capacity

    QAR1,400.00
    The Simplex 4100-3109 (Hardware PCB Part Number: 566-239) is a high-performance IDNet 2 addressable loop interface card designed for Simplex 4100ES and 4100U Fire Alarm Control Panels (FACPs). This crucial expansion module acts as the central communication hub between your fire alarm control panel and intelligent, addressable field devices.
    Engineered for flexibility and robust survivability, this IDNet 2 card manages up to 250 addressable points across its signaling line circuits (SLCs), providing reliable data transmission and power to addressable smoke detectors, heat detectors, monitor modules, and control points.
  • Simplex 4100-5401 ES Power Supply Module

    Simplex 4100-5401 ES Power Supply Module

    QAR2,250.00

    The Simplex 4100-5401 ES-PS Power Supply Module is a primary system power supply designed for Simplex 4100ES addressable fire alarm control units. It provides regulated system power, battery charging, auxiliary outputs, and expansion capability for compatible option cards installed in the control panel.

    The module operates from a 120–240 VAC input and converts power to regulated 24 VDC for the fire alarm control panel and connected field devices. It also includes a dual-rate, temperature-compensated battery charger capable of charging sealed lead-acid batteries up to 110 Ah when used with an external battery cabinet.

  • Simplex 4100-9701 ES-PS Master Controller

    Simplex 4100-9701 ES-PS Master Controller

    QAR13,500.00
    The Simplex 4100-9701 is a core hardware assembly for the Simplex 4100ES Fire Alarm Control Panel (FACP). Specifically, this part number designates the ES-PS Master Controller Bay equipped with an English 2×40 character LCD user interface.
    While a base master controller natively includes a standard dual-loop card, your specific system configuration contains 4 Addressable Loops (achieved via an expansion module) and 2 Notification Appliance Circuits (NACs).

  • Simplex 4606-9101 LCD Annunciator

    Simplex 4606-9101 LCD Annunciator

    The Simplex 4606-9101 is a remote LCD Annunciator designed to mirror fire alarm control panel information at a location away from the main panel. It allows building staff and emergency personnel to monitor and control system status from a convenient entry point, like a lobby or guard station.

  • Simplex 4906-9105 WP AV Non-Add Wall MT Conventional Flasher Red

    Simplex 4906-9105 WP AV Non-Add Wall MT Conventional Flasher Red

    QAR180.00

    The Simplex 4906-9105 is a non-addressable, weatherproof multi-candela strobe designed for wall mounting in fire alarm systems. Housed in a rugged, UV-stable red thermoplastic enclosure, this unit provides high-visibility visual alerts in harsh indoor or outdoor environments with extended temperature and humidity variations.

  • Simplex 4906-9127 Wall Mount TrueAlert Horn Strobe

    Simplex 4906-9127 Wall Mount TrueAlert Horn Strobe

    QAR180.00

    The Simplex 4906-9127 is a wall-mounted TrueAlert multi-candela audible/visible notification appliance featuring a 24 VDC electronic horn and high-output xenon strobe. Designed for SmartSync two-wire operation, it allows independent horn and strobe control on the same NAC circuit.

    This model provides selectable strobe intensity settings of 15, 30, 75, or 110 candela, minimizing inventory requirements and simplifying field configuration. The horn supports steady, ANSI Temporal, or 60 BPM March Time patterns and operates as “on-until-silenced,” while the strobe operates as “on-until-reset” when used with compatible SmartSync control sources.

    The housing is constructed of rugged, high-impact, flame-retardant thermoplastic and mounts to standard single-gang, double-gang, or 4-inch square electrical boxes.